Watlow EZ-ZONE ST Manual do Utilizador Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 97
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 16
Wa tlow EZ-ZONE
®
ST 15 Chapter 2 Install and Wire
1. Pinch the release levers on the top and
bottom of the control module and lift the
bottom edge forward to detach the unit.
2. With a Phillips screwdriver, remove
the four nearest screws that were un-
der the module.
3. Lift the controller body, exposing
the solid-state relay.
4. Using a Phillips screwdriver, remove the
two screws connecting the solid-state relay
to the heat sink.
Replacing the Solid-State Relay
1. Using a Phillips screwdriver, replace
the two screws connecting the solid-
state relay to the heat sink.
2. Place the controller body over the
solid-state relay and, using a Phillips
screwdriver, replace the four screws
securing it.
3. Snap the control module in place,
bottom edge first.
Note:
For controller models without a contactor (ST _ _-A _ _ _-_ _ __),
the solid-state relay must be mounted with the larger power
terminals on the top and the smaller control terminals on the bot-
tom.
Replacing the Solid-State Relay
on a Controller without a Contactor (ST _ _-A _ _ _-_ _ _ _)
Note:
Factory calibration is done using control and base modules as
matched pairs. Due to this fact, current detection (if turned on) may
not read accurately if a control module is placed into another base
module.