Series 988LF
1/8 DIN Microprocessor-Based Temperature/Process Controller
0600-0009-0000 Rev C
October 1999
Supersedes: 0600-0009-0000 Rev B
$10.00
Made in the U.S.A.
Printed on Recycled Paper 10% Postconsumer Waste
Users Manual
Includes 986L, 987L, 988L, and 989L
User Level Targeted:
New User .............................. go to page i
Experienced User................... go to page 2.1
Expert User............................. go to page A.8
Installers:
Setup ..................................... go to page 4.1
Wiring & Installation................ go to page 2.1
Watlow Controls
1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580
Phone: (507) 454-5300, Fax: (507) 452-4507 http://www.watlow.com
Registered Company
Winona, Minnesota USA
ISO 9001
96
TOTAL
3 Year Warranty
CUS
CUS
TOMER
SATISFACTI
CTI
ON
Vista de página 0
1 2 3 4 5 6 ... 63 64

Resumo do Conteúdo

Página 1 - User’s Manual

Series 988LF1/8 DIN Microprocessor-Based Temperature/Process Controller0600-0009-0000 Rev COctober 1999Supersedes: 0600-0009-0000 Rev B$10.00Made in t

Página 2 - Table of Contents

1.4 WATLOW Series 988LF User’s ManualHardware Setup, Chapter 1Notes

Página 3 - Series 988LF Controllers

WATLOW Series 988LF User’s Manual 2.1Installation and Wiring, Chapter 2Chapter 2 Installation and WiringPanel CutoutMaximum PanelThickness0.38" (

Página 4 - Introduction

2.2 WATLOW Series 988LF User’s ManualInstallation and Wiring, Chapter 2InstallationInstalling the Series 988LFInstalling and mounting requires access

Página 5

WATLOW Series 988LF User’s Manual 2.3Installation and Wiring, Chapter 2WiringWiring the Series 988LFWiring options depend on the model number and DIP

Página 6

Wiring 0-20 and 4-20mA Process InputsCertain “transmitters” used in process input applications are producinginternal resistor failures in the Watlow S

Página 7 - Chapter 1 Hardware Setup

WATLOW Series 988LF User’s Manual 2.5Installation and Wiring, Chapter 2Wiring ExampleFigure 2.5 - System wiringexample.988L-10CA-AARRrear view(+)10922

Página 8 - DIP Switches

Wiring NotesL1 L2powerearth ground1121 22çWARNING:To avoid damage toproperty and equip-ment, and/or injuryof loss of life, useNational ElectricCode (N

Página 9

WATLOW Series 988LF User’s Manual 2.7Installation and Wiring, Chapter 2Figure 2.7c — 0-5VÎÎ, 1-5VÎÎor 0-10VÎÎ(dc) ProcessUniversal signal conditioner9

Página 10 - Hardware Setup, Chapter 1

2.8 WATLOW Series 988LF User’s ManualInstallation and Wiring, Chapter 2Figure 2.8d — 0-20mA or 4-20mA ProcessUniversal signal conditioner98 _ L - _ 2

Página 11 - Panel Cutout

WATLOW Series 988LF User’s Manual 2.9Installation and Wiring, Chapter 2Figure 2.9a — AC OutputsSolid-state Relay with Contact Suppression98 _ L - _ _

Página 12 - Installation

Introduction to the Watlow Series 988LFControllersii Using this Manualii Document Every Stepiii Notes, Cautions and Warningsiii Technical Assistanceii

Página 13

Figure 2.10a — AC OutputsSolid-state Relay with Contact Suppression98 _ L - _ _ _ B- A A _ _0.5 amps, minimum off-state impedance: 20KΩElectromechanic

Página 14 - Process wiring

WATLOW Series 988LF User’s Manual 3.1Front Panel and Display Loop, Chapter 3Upper DisplayIndicates the actual process value,prompt parameter value or

Página 15 - Wiring Example

3.2 WATLOW Series 988LF User’s ManualFront Panel and Display Loop, Chapter 3Display LoopDisplay LoopThe Display Loop is the “home” state of the Series

Página 16 - Wiring Notes

SetupSetup Menu, Chapter 4 WATLOW Series 988LF Users Manual 4.1Chapter 4 The Setup MenuNavigating the Setup MenuThe Setup Menu displays the parameters

Página 17 - Input 1 Wiring

Setup4.2 WATLOW Series 988LF Users Manual Setup Menu, Chapter 4Setup Prompts❸ Use the Mode key µ to advance through theSetup Menu. You will not see e

Página 18 - Input 2 Wiring

SetupSetup Menu, Chapter 4 WATLOW Series 988LF Users Manual 4.3[`In1]çCaution:Changing the value of[`In1] changes mostother prompts to thefactory defa

Página 19 - Output 1 Wiring

Setup4.4 WATLOW Series 988LF Users Manual Setup Menu, Chapter 4Range Low and Range HighSelect the low and high range for input 1. These prompts limi

Página 20 - Output 2 Wiring

SetupSetup Menu, Chapter 4 WATLOW Series 988LF Users Manual 4.5[`rL1][`rH1]Range Low and RangeHigh continued fromprevious page.NOTE:The range high [`

Página 21 - Keys and Displays

Setup4.6 WATLOW Series 988LF Users Manual Setup Menu, Chapter 4[`dEC]DecimalSelect the decimal point location for process type input 1 data. Thisprom

Página 22 - Display Loop

SetupSetup Menu, Chapter 4 WATLOW Series 988LF Users Manual 4.7[`rSP]Remote Set Point Inputcontinued from previouspage.Range Low 2 and Range High 2Sel

Página 23 - Chapter 4 The Setup Menu

WATLOW Series 988LF User’s Manual iIntroductionIntroduction To The Watlow Series 988LF ControllersFigure Int.1 - The Series 988LFFeatures.Welcome to t

Página 24 - [`LOC] [`LOC] [`LOC] [`LOC]

Setup4.8 WATLOW Series 988LF Users Manual Setup Menu, Chapter 4Default Default Default↓↓ ↓↓(K) ``°F] [`°C][```H] [-328]…[2500] [-200]…[1371][```t] [-3

Página 25 - [[`In1] [`In1]

SetupSetup Menu, Chapter 4 WATLOW Series 988LF Users Manual 4.9[`Ot2]Output 1Set the way that output 1 will respond to a difference between the setpoi

Página 26 - Range Low and Range High

Setup4.10 WATLOW Series 988LF Users Manual Setup Menu, Chapter 4[`SIL][`ALt]Alarm TypeSelects the alarm type when Output 2 has been selected as an ala

Página 27 - [`rtd [`rtd

OperationsOperations Menu, Chapter 5 WATLOW Series 988LF Users Manual 5.1Navigating the Operation Menus❶ To reach the Operation Menus, begin in theDis

Página 28 - Remote Set Point Input

Operations5.2 WATLOW Series 988LF Users Manual Operations Menu, Chapter 5Display Prompts❸ Use the Mode key µ to advance through the OperationsMenu. Y

Página 29

OperationsOperations Menu, Chapter 5 WATLOW Series 988LF Users Manual 5.3[`rE1]Reset, Output 1Tune the control action to eliminate the offset or droop

Página 30 - [`C_F] [`C_F]

Operations5.4 WATLOW Series 988LF Users Manual Operations Menu, Chapter 5Rate, Output 2Tune the rate to eliminate overshoot on startup or after the se

Página 31 - [``Ht] [``CL]

OperationsOperations Menu, Chapter 5 WATLOW Series 988LF Users Manual 5.5Dead BandSelect the width of the zone between the action of the heating(rever

Página 32 - [`OFF] [``On]

Operations5.6 WATLOW Series 988LF Users Manual Operations Menu, Chapter 5Alarm HiSelect the high trigger value for the output 2 alarm. Represents the

Página 33 - Chapter 5 The Operation Menu

OperationsOperations Menu, Chapter 5 WATLOW Series 988LF Users Manual 5.7Local-remoteSelects a local or remote set point. With [```r] selected the co

Página 34 - Operations

ii WATLOW Series 988LF User’s ManualIntroductionIntroductionUsing this ManualThis manual provides the information you will need to install and operate

Página 35

Operations5.8 WATLOW Series 988LF Users Manual Operations Menu, Chapter 5Notes

Página 36

Factory Menus, Chapter 6 WATLOW Series 988LF Users Manual 6.1Chapter 6 The Factory Menus❶ Press the Up-arrow > and Down-arrow < keys together an

Página 37

6.2 WATLOW Series 988LF Users Manual Factory Menus, Chapter 6Factory Ship DateShows the date that the final factory control test was performed. Thefi

Página 38

Factory Menus, Chapter 6 WATLOW Series 988LF Users Manual 6.3Inputs 1 and 2 Module TypesDisplays which input module is installed in the controller. P

Página 39

6.4 WATLOW Series 988LF Users Manual Factory Menus, Chapter 6Test OutputsThis prompt tests each output. To run the test, scroll through theDiagnostic

Página 40

Factory Menus, Chapter 6 WATLOW Series 988LF Users Manual 6.5❶ Press the Up-arrow > and Down-arrow< keys together and hold until the [`LOC]promp

Página 41 - Chapter 6 The Factory Menus

6.6 WATLOW Series 988LF Users Manual Factory Menus, Chapter 6Notes

Página 42 - Factory-Diagnostics

Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7 WATLOW Series 988LF Users Manual 7.1Chapter 7 Tuning, Manual Operation,Alarms and Error C

Página 43

7.2 WATLOW Series 988LF Users Manual Tuning, Manual Operation, Alarms, and Error Codes, Chapter 74. When tuning is complete, the displays return to th

Página 44

Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7 WATLOW Series 988LF Users Manual 7.3Manual and Automatic OperationTo change from auto to

Página 45 - Factory-Calibration

IntroductionWATLOW Series 988LF User’s Manual iiiIntroductionNotes, Cautions and WarningsWe use note, caution and warning symbols throughout this book

Página 46

7.4 WATLOW Series 988LF Users Manual Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7Using AlarmsOutput 2 of the Series 988LF can function

Página 47 - Alarms and Error Codes

Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7 WATLOW Series 988LF Users Manual 7.5Error CodesNOTE:To view the error code,press the Auto

Página 48 - Manual Tuning

7.6 WATLOW Series 988LF Users Manual Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7Error CodesNOTE:An alarm display will bemasked by an

Página 49

Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7 WATLOW Series 988LF Users Manual 7.7Notes

Página 50 - Using Alarms

7.8 WATLOW Series 988LF Users Manual Tuning, Manual Operation, Alarms, and Error Codes, Chapter 7Notes

Página 51 - Error Codes

Appendix WATLOW Series 988LF Users Manual A.1Warranty/ReturnsWarrantyThe Watlow Series 988LF is warranted to be free ofdefects in material and workman

Página 52

A.2 WATLOW Series 988LF Users Manual AppendixGlossaryannunciator — A visual display that uses pilot lights toindicate the former or existing condition

Página 53

Appendix WATLOW Series 988LF Users Manual A.3NEMA 4X — A NEMA specification for determining resistanceto moisture infiltration. This rating certifies

Página 54

A.4 WATLOW Series 988LF Users Manual AppendixIndex%OUT LED 3.10-5VÎ (dc) process wiringinput 1 2.7remote set point option 2.8output 1 2.90-10VÎ (d

Página 55 - Appendix

Appendix WATLOW Series 988LF Users Manual A.5Q, Rrange high 1 4.4 - 4.5range high 2 4.7 - 4.8range low 1 4.4 - 4.5range low 2 4.7 - 4.8rateoutput

Página 56 - Glossary

iv WATLOW Series 988LF User’s ManualIntroductionNotes

Página 57

A.6 WATLOW Series 988LF Users Manual AppendixSpecificationsLine Voltage/Power• 100-240Vı(ac/dc) +10%, -15%; 50/60Hz, ±5%• 24-28Vı(ac/dc) +10%, -15%;

Página 58

Appendix WATLOW Series 988LF Users Manual A.7Ordering Information–(1319)To order, complete the code number to the right with the information below:9 8

Página 59 - Index / Prompts

A.8 WATLOW Series 988LF Users Manual AppendixFigure A.8-The Series 988LF MapNOTE:This is a completelisting of all Series988LF prompts.Not all prompts

Página 60 - Specifications

Erwin D. Lowell Winona, Minnesota, USAName of Authorized Representative Place of IssueGeneral Manager January 9, 1996Title of Authorized Representativ

Página 61 - Model Number

Watlow Series 988LF User’s ManualWatlow Controls, 1241 Bundy Boulevard., P.O. Box 5580, Winona, Minnesota USA 55987-5580Phone: (507) 454-5300, Fax: (

Página 62 - Menu Overview

WATLOW Series 988LF User’s Manual 1.1Hardware Setup, Chapter 1Chapter 1 Hardware SetupDIP Switch Locations and FunctionsThe Watlow Series 988LF has at

Página 63 - Declaration of Conformity

1.2 WATLOW Series 988LF User’s ManualHardware Setup, Chapter 1DIP SwitchesFigure 1.2 - Input DIP switches.Input 1 Input 2 (Remote Set Point)(98_L-2___

Página 64

WATLOW Series 988LF User’s Manual 1.3Hardware Setup, Chapter 1DIP SwitchesFigure 1.3 - Lockout DIP switch.no hardware lockout or(Switch 1 has no effec